<%NUMBERING1%>.<%NUMBERING2%>.<%NUMBERING3%> PRTG Manual: SNMP Dell PowerEdge System Health Sensor

The SNMP Dell PowerEdge System Health sensor monitors the system health of a Dell PowerEdge server via the Simple Network Management Protocol (SNMP).

SNMP Dell PowerEdge System Health Sensor

SNMP Dell PowerEdge System Health Sensor

i_square_cyanFor a detailed list and descriptions of the channels that this sensor can show, see section Channel List.

Sensor in Other Languages

  • Dutch: SNMP Dell PowerEdge Systeemstatus
  • French: Dell PowerEdge état du système (SNMP)
  • German: SNMP Dell PowerEdge Systemzustand
  • Japanese: SNMP Dell PowerEdge システムの正常性
  • Portuguese: Saúde do sistema Dell PowerEdge (SNMP)
  • Russian: Работоспособность системы Dell PowerEdge по SNMP
  • Simplified Chinese: SNMP Dell PowerEdge 系统健康状况
  • Spanish: Salud de sistema Dell PowerEdge (SNMP)

Remarks

Consider the following remarks and requirements for this sensor:

Remark

Description

Dell OpenManage Server Administrator or iDRAC 7

  • This sensor requires Integrated Dell Remote Access Controller (iDRAC) 7 or the Dell OpenManage Server Administrator (OMSA) on the target system.
  • Make sure that you enable SNMP in the OMSA.

i_square_cyanFor more information, see the Knowledge Base: What do I need to monitor Dell servers?

i_round_blueYou can also monitor Dell PowerEdge servers with this sensor via iDRAC 7.

IPv6

  • This sensor supports IPv6.

Performance impact

  • This sensor has a very low performance impact.

Lookups

  • This sensor uses lookups to determine the status values of one or more channels.

Knowledge Base

Basic Sensor Settings

Basic Sensor Settings

Basic Sensor Settings

The sensor has the following default tags that are automatically predefined in the sensor's settings when you add the sensor:

  • dell
  • snmpdell
  • snmpdellsystemhealthsensor
  • systemhealth

i_square_cyanFor more information about basic sensor settings, see section Sensor Settings.

Dell PowerEdge System Health Specific

Dell PowerEdge System Health Specific

Dell PowerEdge System Health Specific

Setting

Description

Chassis

The chassis that this sensor monitors.

Channel Mask

The channel mask that describes which channels are available.

Data Source

The interface that PRTG uses to get monitoring data. This is either Dell OMSA or iDRAC.

Sensor Display

Sensor Display

Sensor Display

Setting

Description

Primary Channel

Select a channel from the list to define it as the primary channel. In the device tree, PRTG displays the last value of the primary channel below the sensor's name. The available options depend on what channels are available for this sensor.

i_round_blueYou can set a different primary channel later by clicking b_channel_primary below a channel gauge on the sensor's Overview tab.

Graph Type

Define how this sensor shows different channels:

  • Show channels independently (default): Show a graph for each channel.
  • Stack channels on top of each other: Stack channels on top of each other to create a multi-channel graph. This generates a graph that visualizes the different components of your total traffic.
    i_round_redYou cannot use this option in combination with manual Vertical Axis Scaling (available in the channel settings).

Stack Unit

This setting is only visible if you select Stack channels on top of each other above.

Select a unit from the list. PRTG stacks all channels with this unit on top of each other. By default, you cannot exclude single channels from stacking if they use the selected unit. However, there is an advanced procedure to do so.

Inherited Settings

By default, all of these settings are inherited from objects that are higher in the hierarchy. We recommend that you change them centrally in the root group settings if necessary. To change a setting for this object only, click b_inherited_enabled under the corresponding setting name to disable the inheritance and to display its options.

i_square_cyanFor more information, see section Inheritance of Settings.

Channel List

i_round_blueWhich channels the sensor actually shows might depend on the target device, the available components, and the sensor setup.

Channel

Description

Ampere Status

The ampere status

  • Up status: OK
  • Warning status: Non Critical
  • Down status: Critical, Non Recoverable, Other, Unknown

Battery Status

The battery status

  • Up status: OK
  • Warning status: Non Critical
  • Down status: Critical, Non Recoverable, Other, Unknown

Chassis Status

The chassis status

  • Up status: OK
  • Warning status: Non Critical
  • Down status: Critical, Non Recoverable, Other, Unknown

Cooling Device Status

The cooling device status

  • Up status: OK
  • Warning status: Non Critical
  • Down status: Critical, Non Recoverable, Other, Unknown

Cooling Unit Status

The cooling unit status

  • Up status: OK
  • Warning status: Non Critical
  • Down status: Critical, Non Recoverable, Other, Unknown

Downtime

In the channel table on the Overview tab, this channel never shows any values. PRTG uses this channel in graphs and reports to show the amount of time in which the sensor was in the Down status

Global System Status

The global system status

  • Up status: OK
  • Warning status: Non Critical
  • Down status: Critical, Non Recoverable, Other, Unknown

i_round_blueThis channel is the primary channel by default.

Intrusion Status

The intrusion status

  • Up status: OK
  • Warning status: Non Critical
  • Down status: Critical, Non Recoverable, Other, Unknown

Memory Device Status

The memory device status

  • Up status: OK
  • Warning status: Non Critical
  • Down status: Critical, Non Recoverable, Other, Unknown

Power Supply Status

The power supply status

  • Up status: OK
  • Warning status: Non Critical
  • Down status: Critical, Non Recoverable, Other, Unknown

Power Unit Status

The power unit status

  • Up status: OK
  • Warning status: Non Critical
  • Down status: Critical, Non Recoverable, Other, Unknown

Processor Status

The processor status

  • Up status: OK
  • Warning status: Non Critical
  • Down status: Critical, Non Recoverable, Other, Unknown

Temperature Status

The temperature status

  • Up status: OK
  • Warning status: Non Critical
  • Down status: Critical, Non Recoverable, Other, Unknown

Voltage Status

The voltage status

  • Up status: OK
  • Warning status: Non Critical
  • Down status: Critical, Non Recoverable, Other, Unknown

More

i_square_blueKNOWLEDGE BASE

Why does my Dell PowerEdge System Health sensor show a power unit status error after iDRAC update?

What do I need to monitor Dell servers?

I can't add Dell PowerEdge sensors to PRTG. What can I do?

What security features does PRTG include?

My SNMP sensors don’t work. What can I do?